SC680 CLAMP-ON METER W/TEMP/CAP STAND ALONE FIELDPIECE SWIVEL
Clamp Meter
Type Digital
Parameter Measured AC/DC Voltage, Non-Contact Voltage, AC/DC Current, Capacitance, Resistance, Frequency, Continuity, Diode Test, Duty Cycle, Temperature
Display Type LCD Backlight
AC Voltage Range 600 Volt
DC Voltage Range 600 Volt
AC Current Range 400 Amp
DC Current Range 500 Microamp
Resistance Range 50 Mega Ohm
Frequency Range 50 to 500 Hertz (Voltage Mode), 10 to 400 Hertz (Clamp), 10 Hertz to 1 Mega Hertz (Lead)
Battery Type 9 Volt 100 Hour Alkaline
Jaw Opening 1.2 Inch
Size 79 Millimeter Width x 45 Millimeter Depth x 233 Millimeter Height
Inclusion ADLS2 Deluxe Silicone Lead Set with Gold Plated Tip and Removable Sheath, ATB1 Wrap Tab K-Type Thermocouple, Velcro Strap, 9 Volt Alkaline Battery, ANC12 Padded Case
Approval UL (Canada and US), CE, C-Tick, WEEE
RoHS Compliant
Capacitance 5000 Microfarad
Temperature Rating -30 to 932 Deg F
Accuracy 1.2 Percent +/-8 at 0.0001 Resolution (AC Voltage), 2 Percent +/-10 at 0.01 Resolution (AC Current), 0.5 Percent +/-2 at 0.0001 Resolution (DC Voltage), 1 Percent +/-2 at 0.1 Resolution (DC Current), 1 Percent +/-5 at 0.1 Resolution (Resistance), 3 Percent +/-5 at 0.001 Resolution (Capacitance), 0.1 Percent +/-5 at / 0.1 Resolution (Clamp/Lead Frequency), 2 Percent +/-10 at 0.1 Resolution (Duty Cycle), +/-1 Deg F at 0.1 Resolution (Temperature)
Backlight 60 Second Duration with Auto-Off Blue Color
Dual Display 5000 Count
Measurement Rate 3.3 Times per Second Nominal
Zero Automatic
Operating Environment 32 to 122 Deg F Less than 70 Percent Relative Humidity
Temperature Co-Efficient 0.1x per Deg C
Auto Power-Off Approximately 30 Minute
Altitude up to 6562 Foot
Safety Degree CATIII 600V, Class II and Pollution Degree 2
Application Indoor, HVAC/R
Type Digital
Parameter Measured AC/DC Voltage, Non-Contact Voltage, AC/DC Current, Capacitance, Resistance, Frequency, Continuity, Diode Test, Duty Cycle, Temperature
Display Type LCD Backlight
AC Voltage Range 600 Volt
DC Voltage Range 600 Volt
AC Current Range 400 Amp
DC Current Range 500 Microamp
Resistance Range 50 Mega Ohm
Frequency Range 50 to 500 Hertz (Voltage Mode), 10 to 400 Hertz (Clamp), 10 Hertz to 1 Mega Hertz (Lead)
Battery Type 9 Volt 100 Hour Alkaline
Jaw Opening 1.2 Inch
Size 79 Millimeter Width x 45 Millimeter Depth x 233 Millimeter Height
Inclusion ADLS2 Deluxe Silicone Lead Set with Gold Plated Tip and Removable Sheath, ATB1 Wrap Tab K-Type Thermocouple, Velcro Strap, 9 Volt Alkaline Battery, ANC12 Padded Case
Approval UL (Canada and US), CE, C-Tick, WEEE
RoHS Compliant
Capacitance 5000 Microfarad
Temperature Rating -30 to 932 Deg F
Accuracy 1.2 Percent +/-8 at 0.0001 Resolution (AC Voltage), 2 Percent +/-10 at 0.01 Resolution (AC Current), 0.5 Percent +/-2 at 0.0001 Resolution (DC Voltage), 1 Percent +/-2 at 0.1 Resolution (DC Current), 1 Percent +/-5 at 0.1 Resolution (Resistance), 3 Percent +/-5 at 0.001 Resolution (Capacitance), 0.1 Percent +/-5 at / 0.1 Resolution (Clamp/Lead Frequency), 2 Percent +/-10 at 0.1 Resolution (Duty Cycle), +/-1 Deg F at 0.1 Resolution (Temperature)
Backlight 60 Second Duration with Auto-Off Blue Color
Dual Display 5000 Count
Measurement Rate 3.3 Times per Second Nominal
Zero Automatic
Operating Environment 32 to 122 Deg F Less than 70 Percent Relative Humidity
Temperature Co-Efficient 0.1x per Deg C
Auto Power-Off Approximately 30 Minute
Altitude up to 6562 Foot
Safety Degree CATIII 600V, Class II and Pollution Degree 2
Application Indoor, HVAC/R